Service Purpose

To maintain, delay, improve and improve the performance of the BOP control device and the implementation of professional technical services, so that customers effectively increase the benefits, reduce costs, save materials, optimize management, prolong the service life of equipment, reduce production costs, avoid safety accidents and production technical failure.

Service Reference Standards

  1. Q/HS YF 472-2021
  2. Q/HS 14035-2018
  3. Q/HS 14002
  4. SY/T5053.2-2007
  5. API SPEC.16D(2004)

Testing Process

According to the customer designated testing standard, after-sales service and technical personnel to instrument platform equipment and relief valve check, oil seal, control the time lag, switch action consistent and pressure display and alarm functions, accumulator of key projects, such as wall thickness detection, and where is not in conformity with the requirements of the careful analysis of the causes, overhaul, such as found parts damaged, Immediately assist the on-site mechanic to replace the parts, and issue the original manufacturer's inspection report after the completion of the test.

Inspect accumulator wall thickness

 

Detecting nitrogen pressure

 

Replace damaged accumulator bladders

 

Testing Triplex pump Fabric-rubber packing and motor chain

 

Removal of pneumatic pump

 

Remove and check the 3-position 4-way rotary valve and replace the seal

 

×